Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1090999.015
Citation: 01008A
Citation Type: Serious
Abatement Date: 04/01/2016 2
Initial Penalty: $4,900.00
Current Penalty: $1,100.00
Issuance Date: 03/08/2016
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0418400
Contest Date: 03/28/2016
Final Order: 09/12/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/12/2016 | $1,100.00 | 04/01/2016 | Serious | |
Penalty | C: Contested | 04/04/2016 | $4,900.00 | 04/01/2016 | Serious | |
Penalty | Z: Issued | 03/08/2016 | $4,900.00 | 04/01/2016 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Plant Facility, on or about and at times preceding to September 9, 2015, for employees engaged in performing minor maintenance work including changing belts and troubleshooting equipment did not utilize energy control procedures.