Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1063115.015
Citation: 01008A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,000.00
Current Penalty: $4,550.00
Issuance Date: 07/28/2015
Nr Instances: 1
Nr Exposed: 20
Abatement Date: 08/13/2015
Gravity: 10
Report ID: 0524700
Contest Date: 08/21/2015
Final Order: 04/13/2016
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/13/2016 | $4,550.00 | 08/13/2015 | Serious | |
Penalty | C: Contested | 08/26/2015 | $7,000.00 | 08/13/2015 | Serious | |
Penalty | Z: Issued | 07/28/2015 | $7,000.00 | 08/13/2015 | Serious |
Text For Citation: 01 Item/Group: 008A Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a. Wilbert, Inc. - Bellevue, OH: On or about February 2, 2015, the employer did not ensure that employees were protected from hazardous energy sources while troubleshooting and cleaning a mold located in the A57 plastic injection press. The press was not shut down and energy isolating devices were not used when employees entered the press for troubleshooting and cleaning tasks.