Violation Detail
Standard Cited: 19100242 B Hand and portable powered tools and equipment, general.
Inspection Nr: 980337.015
Citation: 01008
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $2,400.00
Current Penalty: $1,560.00
Issuance Date: 11/28/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/31/2015
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 01/30/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/30/2015 | $1,560.00 | 03/31/2015 | Serious | |
| Penalty | Z: Issued | 11/28/2014 | $2,400.00 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 psi: On or about June 10, 2014 at 120 McArthur Road, Marble Hill, GA: Compressed air was used to blow dust off parts and other surfaces. The employees were exposed to cut and laceration hazards, and the hazard of an embolism when the air at the tip of the nozzle used exceeded 30 psi.