Violation Detail
Standard Cited: 19100119 J02 Process safety management of highly hazardous chemicals.
Inspection Nr: 314054685
Citation: 01008
Citation Type: Serious
Abatement Status: X
Initial Penalty: $1,250.00
Current Penalty:
Issuance Date: 06/25/2010
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 11/30/2010
Gravity: 03
Report ID: 0728900
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 07/13/2010 | 11/30/2010 | Serious | ||
| Penalty | Z: Issued | 06/25/2010 | $1,250.00 | 08/27/2010 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard: CHEMNEP
29 CFR 1910.119(j)(2): Equalizer Midwest, Inc. - Hastings, NE - The employer did not establish and implement written procedures to maintain the on-going mechanical integrity of process equipment. Facility mechanical integrity program did not establish and implement written procedures to address repair, replacement and/or testing of process equipment including, but not limited to pressure relief valves, pressure vessels and piping. Abatement certification is required for this violation. The abatement certification sheet is enclosed with the citations.