Violation Detail
Standard Cited: 50104 A General Duty
Inspection Nr: 311599989
Citation: 01008
Citation Type: Serious
Abatement Status: A
Initial Penalty: $2,450.00
Current Penalty: $2,450.00
Issuance Date: 05/23/2008
Nr Instances: 1
Nr Exposed: 53
Abatement Date: 06/25/2008
Gravity: 07
Report ID: 0352420
Contest Date:
Final Order:
Related Event Code (REC):
Emphasis:
Substance: M102
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/24/2008 | $2,450.00 | 06/25/2008 | Serious | |
| Penalty | Z: Issued | 05/23/2008 | $2,450.00 | 06/25/2008 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard: DUST&FUMES
Labor and Employment Article, Section 5-104(a): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a)Date of Violation:01/15/08 Location:Nomex Room Condition:Employees were exposed to dust explosion, deflagration, and other fire hazards from the CNC machines dust collection systems located inside the nomex room. Among other methods, one feasible and acceptable method to abate this hazard is to relocate the dust collection systems outside the building. Perform a process hazard analysis and assessment on the machining/shaping/forming of nomex products and the dust collection systems. Certification verifying the design, installation, operation and maintenance of nomex explosive/combustible dust collection system met all applicable standards including, but not limited to NFPA 654. Abatement documentation (photographs, receipts, copies of programs, training certification, etc.) is required for this item.
Translate