Violation Detail
Standard Cited: 19100305 J04 V Wiring methods, components, and equipment for general use.
Inspection Nr: 1766015.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $15,606.00
Current Penalty: $7,803.00
Issuance Date: 01/24/2025
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 02/20/2025
Gravity: 5
Report ID: 0626300
Contest Date:
Final Order: 03/03/2025
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/03/2025 | $7,803.00 | 02/20/2025 | Serious | |
Penalty | Z: Issued | 01/24/2025 | $15,606.00 | 02/20/2025 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.305(j)(4)(v): The disconnecting means was not readily accessible: On or about July 31, 2024, employees were not protected from dangerous machinery in that: (a) The taper roll machine (TG1) on Gogan line 1 did not have a readily accessible disconnecting means because it was mounted to the southwest wall behind the machine and not the front of the machine where the operator stood. (b) The squeezer/side taper machine on Gogan line 1 did not have a readily accessible disconnecting means because it was mounted to the southwest wall behind the machine and not the front of the machine where the operator stood.