Violation Detail
Standard Cited: 19100213 A12 Woodworking machinery requirements.
Inspection Nr: 1603752.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,801.00
Current Penalty: $3,770.65
Issuance Date: 12/19/2022
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/17/2023
Gravity: 10
Report ID: 0317300
Contest Date: 01/31/2023
Final Order: 06/05/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 08/07/2023 | $5,801.00 | 01/17/2023 | Serious | |
Penalty | F: Formal Settlement | 06/05/2023 | $3,770.65 | 01/17/2023 | Serious | |
Penalty | Z: Issued | 12/19/2022 | $5,801.00 | 01/17/2023 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.213(a)(12):The portion of circular saw(s) beneath or behind the table, where there was a possibility of contact with the saw, was not covered with a guard or exhaust hood). a) 1234 South Governors Avenue, Dover, DE 19904 (Warehouse): On or about June 23, 2022, the employer permitted employees to use a table saw without a guard or exhaust hood.