Violation Detail
Standard Cited: 19100265 D01 II B Sawmills.
Inspection Nr: 1544668.015
Citation: 01008
Citation Type: Serious
Abatement Date: 02/23/2022 2
Initial Penalty: $13,052.00
Current Penalty: $7,831.20
Issuance Date: 01/27/2022
Nr Instances: 1
Nr Exposed: 15
Related Event Code (REC):
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 02/18/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/18/2022 | $7,831.20 | 02/23/2022 | Serious | |
Penalty | Z: Issued | 01/27/2022 | $13,052.00 | 02/23/2022 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.265(d)(1)(ii)(b): The lifting cylinders of all hydraulically operated log handling machines was not equipped with a positive device for preventing the uncontrolled lowering of the load or forks in case of a failure in the hydraulic system: (a) On or about November 2, 2021, and at times prior thereto at the Cooper Scragg mill, the log loader had visible hydraulic leaks from the hoses and cylinders exposing employees to struck-by and crushed-by hazards.