Violation Detail
Standard Cited: 19100254 D09 III Arc welding and cutting.
This violation item has been deleted.
Inspection Nr: 1522450.015
Citation: 01008
Citation Type: Serious
Abatement Status:
Initial Penalty: $8,582.00
Current Penalty: $0.00
Issuance Date: 09/14/2021
Nr Instances: 2
Nr Exposed: 3
Abatement Date: 10/01/2021
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 11/29/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/29/2021 | $0.00 | 10/01/2021 | Serious | |
Penalty | Z: Issued | 09/14/2021 | $8,582.00 | 10/01/2021 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced: The employer does not ensure welding cables with exposed copper wires were repaired or removed from service, at the CM Trailers facility: a) This violation was observed on or about August 3, 2021, in the robot cell, two welding cables had exposed copper wires, exposing employees to burns and shock hazards b) This violation was observed on or about August 3, 2021, on welding line#2, a welding cable damaged exposing copper wires, exposing employees to burns and shock hazards Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure welders with exposed copper wires are repaired or removed from service.