Violation Detail
Standard Cited: 19100147 C04 II C The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1428759.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,494.00
Current Penalty: $0.00
Issuance Date: 02/20/2020
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 03/26/2020
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 03/16/2020
Related Event Code (REC): R
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 03/16/2020 | $0.00 | 03/26/2020 | Serious | |
| Penalty | Z: Issued | 02/20/2020 | $13,494.00 | 03/26/2020 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. The employer is failing to protect employees from caught-in, struck-by, electric shock, and amputation hazards associated with servicing equipment. The company had not developed written machine specific lockout tagout procedures for the Rocket Launcher a 3 hopper fabricated machine. This was most recently documented on September 5, 2019 at a worksite located at 1010 Century Ave, Branson, Missouri