Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1393269.015
Citation: 01008
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $8,525.00
Current Penalty: $6,033.00
Issuance Date: 07/15/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 03/01/2020
Gravity:
Report ID: 0522500
Contest Date: 08/05/2019
Final Order: 03/04/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 03/04/2020 | $6,033.00 | 03/01/2020 | Other | |
Penalty | C: Contested | 08/21/2019 | $8,525.00 | 08/19/2019 | Serious | |
Penalty | Z: Issued | 07/15/2019 | $8,525.00 | 08/19/2019 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. a. On or about April 15, 2019, the employer did not conduct a periodic inspection of the energy control procedures.