Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1391183.015
Citation: 01008
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 09/26/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 10/30/2019
Gravity: 10
Report ID: 0112600
Contest Date: 11/15/2019
Final Order: 08/13/2020
Related Event Code (REC): A;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | D: Govt Dismissed | 08/13/2020 | $0.00 | 10/30/2019 | Serious | |
Penalty | C: Contested | 11/19/2019 | $11,934.00 | 10/30/2019 | Serious | |
Penalty | Z: Issued | 09/26/2019 | $11,934.00 | 10/30/2019 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) Site: In Building 1, On the Coating Line, At the aisle side of the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 the guard for the Main Drive had holes cut in it to allow the unprotected rotating shafts to protrude through the guard and pose hazards to Coating Line Operators.