Violation Detail
Standard Cited: 19100107 G02 Spray finishing using flammable and combustible materials.
Inspection Nr: 1381588.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,304.00
Current Penalty: $2,652.00
Issuance Date: 04/25/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/15/2019
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 05/20/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/20/2019 | $2,652.00 | 05/15/2019 | Serious | |
Penalty | Z: Issued | 04/25/2019 | $5,304.00 | 05/15/2019 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material: On or about February 28, 2018, the spray booth had excessive accumulation of combustible residues created by spray operations.