Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1345312.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,956.00
Current Penalty: $1,478.00
Issuance Date: 11/29/2018
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/28/2019
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 12/26/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/26/2018 | $1,478.00 | 02/28/2019 | Serious | |
Penalty | Z: Issued | 11/29/2018 | $2,956.00 | 12/26/2018 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish an energy control program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occurr and cause injury, the machine or equipment would be isolated, and rendered inoperative: On or about September 10, 2018, the company did not establish a program to protect employees involved with servicing and maintenance of machines and equipment from the unexpected energizing, start up or release of stored energy. Energy sources included, but are not limited to, electrical, pneumatic, and hydraulic. The company maintains and services equipment such as, but not limited to, the Fanuc System R-30IA Mate Robotic Cell used in the spray painting department.