Violation Detail
Standard Cited: 19100265 E05 II A Sawmills.
Inspection Nr: 1313616.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,174.00
Current Penalty: $3,104.00
Issuance Date: 10/24/2018
Nr Instances: 2
Nr Exposed: 12
Abatement Date: 11/30/2018
Gravity: 10
Report ID: 0523900
Contest Date:
Final Order: 11/07/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/07/2018 | $3,104.00 | 11/30/2018 | Serious | |
Penalty | Z: Issued | 10/24/2018 | $5,174.00 | 11/30/2018 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.265(e)(5)(ii)(a): Top(s) and opening(s) in end and side frame(s) of edger(s) were not adequately guarded: (a) Edger; Guarding on the edger did not fully enclose an opening between the top guard and side frame. (b) Edger; Guarding on the edger did not enclose powered out feed rollers.