Violation Detail
Standard Cited: 19100254 D09 III Arc welding and cutting.
Inspection Nr: 1309302.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,114.00
Current Penalty: $4,268.40
Issuance Date: 09/12/2018
Nr Instances: 1
Nr Exposed: 9
Abatement Date: 09/24/2018
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 10/02/2018
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/02/2018 | $4,268.40 | 09/24/2018 | Serious | |
Penalty | Z: Issued | 09/12/2018 | $7,114.00 | 09/24/2018 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors shall be replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions. a. On or about April 17, 2018, in the welding area, the taped electrode cable for the Miller Millermatic 350 (S/N: LK220034N) welder used for gas metal arc welding (GMAW) had damaged insulation exposing the bare conductor.