Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100212 A05 General requirements for all machines.

Inspection Nr: 1251758.015

Citation: 01008

Citation Type: Serious

Abatement Status: Corrected During Inspection

Initial Penalty: $6,973.00

Current Penalty: $3,486.50

Issuance Date: 12/28/2017

Nr Instances: 1

Nr Exposed: 4

Abatement Date:

Gravity: 5

Report ID: 0418400

Contest Date:

Final Order: 01/19/2018

Related Event Code (REC):

Emphasis:


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty I: Informal Settlement 01/19/2018 $3,486.50   Serious  
Penalty Z: Issued 12/28/2017 $6,973.00   Serious  

Text For Citation: 01 Item/Group: 008 Hazard:

29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: (a)Receiving Pit Area, on or about and at times preceding to August 1, 2017, pedestal fan used in truck dumping area had openings measuring up to 5 inches plus, exposing workers to fingertip amputations.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.