Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
Inspection Nr: 1155102.015
Citation: 01008
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $12,471.00
Current Penalty: $11,078.00
Issuance Date: 11/22/2016
Nr Instances: 2
Nr Exposed: 16
Abatement Date: 04/16/2018
Gravity:
Report ID: 0627100
Contest Date: 11/29/2016
Final Order: 03/15/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/15/2018 | $11,078.00 | 04/16/2018 | Other | |
Penalty | C: Contested | 12/02/2016 | $12,471.00 | 12/23/2016 | Serious | |
Penalty | Z: Issued | 11/22/2016 | $12,471.00 | 12/23/2016 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: On/around June 7, 2016 the employer at the Tyson Foods facility in Hope, Arkansas did not ensure that cooling fans in areas where operators enter to monitor and control equipment in the 2nd Process refrigeration system have blade guards. a) The personal cooling fan used by operators in the control room/operator office was in operation without a blade guard. b) The cooling fan for the water pump motor on the condenser unit was in operation with the blade unguarded.