Violation Detail
Standard Cited: 19100217 C02 I A Mechanical power presses.
Inspection Nr: 1139012.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $3,000.00
Issuance Date: 06/10/2016
Nr Instances: 3
Nr Exposed: 6
Abatement Date: 07/25/2016
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 06/30/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/30/2016 | $3,000.00 | 07/25/2016 | Serious | |
Penalty | Z: Issued | 06/10/2016 | $5,000.00 | 06/30/2016 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): On and before April 11, 2016, the horizontal light curtain safeguarding at the part revolution mechanical power presses numbers 2, 4 and 14 were not adequate, in that, the openings at the bottoms and the tops would allow employee access to the dies and guide posts without activating the safeguarding.