Violation Detail
Standard Cited: 19100179 G01 V Overhead and gantry cranes.
Inspection Nr: 1069945.015
Citation: 01008
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,000.00
Current Penalty: $2,800.00
Issuance Date: 12/09/2015
Nr Instances: 1
Nr Exposed: 10
Abatement Date:
Gravity: 5
Report ID: 0522500
Contest Date:
Final Order: 01/06/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/06/2016 | $2,800.00 | Serious | ||
Penalty | Z: Issued | 12/09/2015 | $4,000.00 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions. a. At the workplace, in the roll form area, a Budgit, 2 ton, overhead crane had a pendant control box with none of the buttons marked to identify the functions, thereby exposing employees to a struck-by hazard.