Violation Detail
Standard Cited: 19100217 C02 I A Mechanical power presses.
Inspection Nr: 1049652.015
Citation: 01008
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $5,000.00
Current Penalty: $3,250.00
Issuance Date: 07/30/2015
Nr Instances: 5
Nr Exposed: 231
Abatement Date: 08/25/2015
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 08/18/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/18/2015 | $3,250.00 | 08/25/2015 | Serious | |
| Penalty | Z: Issued | 07/30/2015 | $5,000.00 | 08/25/2015 | Serious |
Text For Citation: 01 Item/Group: 008 Hazard:
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): On or before 03/25/2015, the employer did not ensure that mechanical power presses used throughout the facility were adequately guarded. Equipment includes, but is not limited to the following: a. The hair-pin guarding on the(company# GAK 400220) Bliss mechanical power press located in the press room was not adjusted to prevent entry of hands or fingers into the point of operation. b. Company no. 400022: mechanical power press located in the press room had an opening in the guard which measured approximately 7.5-8 inches and did not prevent entry of hands or fingers into the point of operation. c. The Niagara: mechanical power press (Co. #GEK #140330) that had A and/or B gate guard did not prevent the operator from reaching over into the point-of-operation.
Translate