Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 448973.015
Citation: 01007E
Citation Type: Serious
Abatement Date: 12/19/2012 2
Initial Penalty: $2,800.00
Current Penalty: $0.00
Issuance Date: 11/16/2012
Nr Instances: 3
Nr Exposed: 12
Related Event Code (REC):
Gravity: 10
Report ID: 0728500
Contest Date: 12/10/2012
Final Order: 02/27/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/27/2014 | $0.00 | 12/19/2012 | Serious | |
Penalty | C: Contested | 01/17/2013 | $2,800.00 | 12/19/2012 | Serious | |
Penalty | Z: Issued | 11/16/2012 | $2,800.00 | 12/19/2012 | Serious |
Text For Citation: 01 Item/Group: 007E Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed: (a) Sprockets and chains by the roll case east of the Brewco Band Saw were not guarded; (b) Sprockets and chains at floor level below the roll case east of the edge saw were not guarded; and (c) Sprockets and chains on the transfer table going to the sorting and stacking chain was partially guarded, but the guard had been damaged and not repaired.