Violation Detail
Standard Cited: 19101025 H01 Lead.
Inspection Nr: 1526878.015
Citation: 01007D
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,192.00
Current Penalty: $0.00
Issuance Date: 10/18/2021
Nr Instances: 13
Nr Exposed: 15
Abatement Date: 11/04/2021
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 11/16/2021
Related Event Code (REC):
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/16/2021 | $0.00 | 11/04/2021 | Serious | |
Penalty | Z: Issued | 10/18/2021 | $8,192.00 | 11/04/2021 | Serious |
Text For Citation: 01 Item/Group: 007D Hazard:
29 CFR 1910.1025(h)(1):All surfaces were not maintained as free as practicable of accumulations of lead. (a) At the facility; On or about and times prior to April 22, 2021; the employer did not ensure all workplace surfaces were as free as practicable of the accumulation of lead, exposing the employees to lead hazards. Wipe samples were collected on April 22, 2021 and April 26, 2021 with the following results: a. Bottom of stair rail in back of the building - 6155.400 milligrams per 100 square centimeters b. Table in range corridor, top right corner - 693.830 milligrams per 100 square centimeters c. Gun sales main register, in front of monitor - 217.110 milligrams per 100 square centimeters d. The half face respirator Jacob used, inside chin area - 197.730 milligrams per 100 square centimeters e. Left Coke refrigerator handle, in breakroom - 135.500 milligrams per 100 square centimeters f. White table in breakroom next to fridge, spot in front of microwave - 102.360 milligrams per 100 centimeters g. Keyboard in training room - 97.778 milligrams per 100 square centimeters h. Bottom right corner of the red table in the receiving area - 50.910 milligrams per 100 square centimeters i. Glass counter near the range door - 47.062 milligrams per 100 square centimeters j. Glass counter near the register by the range entrance, left of monitor - 39.237 milligrams per 100 square centimeters k. On/off buttons in auger room, back of building - 19.672 milligrams per 100 square centimeters l. Desk in manager's office, in front of monitor - 17.057 milligrams per 100 square centimeters m. Sales area glass counter near the main register - 15.934 milligrams per 100 square centimeters