Violation Detail
Standard Cited: 19100134 K01 Respiratory Protection.
Inspection Nr: 1511056.015
Citation: 01007C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/21/2021
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 08/04/2021
Gravity: 10
Report ID: 0317000
Contest Date:
Final Order: 08/12/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/12/2021 | $0.00 | 08/04/2021 | Serious | |
Penalty | Z: Issued | 07/21/2021 | $0.00 | 08/04/2021 | Serious |
Text For Citation: 01 Item/Group: 007C Hazard:
29 CFR 1910.134(k)(1):The employer did not provide effective training to ensure that each employee could demonstrate knowledge of 1910.134(k)(1)(i) - (vii): UTCRAS Inc., located at 501 Highland Ave. Morton, PA: (a) UTCRAS, Painting and Welding shops, Building O and Building U: On or about January 21, 2021, the employer did not ensure that employees required to use wear half face respirator such as, but not limited to 3M Series 6000 with organic vapors and Miller LPR 100 with P100 filters received respiratory training.