Violation Detail
Standard Cited: 19100303 B02 General.
Inspection Nr: 1504457.015
Citation: 01007C
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,008.00
Current Penalty: $0.00
Issuance Date: 05/10/2021
Nr Instances: 1
Nr Exposed: 48
Abatement Date:
Gravity: 5
Report ID: 0524500
Contest Date:
Final Order: 06/04/2021
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/04/2021 | $0.00 | Serious | ||
Penalty | Z: Issued | 05/10/2021 | $6,008.00 | Serious |
Text For Citation: 01 Item/Group: 007C Hazard:
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about November 30, 2020, employees working near and operating the EC 500 SX III Molding Machine were exposed electrical hazards because a controller module labeled "autoloader" was powered by an extension cord which was plugged into another extension cord which was plugged into a 120 volt outlet.