Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1724412.015
Citation: 01007B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/12/2024
Nr Instances: 4
Nr Exposed: 3
Abatement Date: 08/07/2024
Gravity: 10
Report ID: 0728500
Contest Date:
Final Order: 08/08/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/08/2024 | $0.00 | 08/07/2024 | Serious | |
Penalty | Z: Issued | 07/12/2024 | $0.00 | 08/07/2024 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): At the worksite located at 1315 North 2nd Street Clinton, MO: On or prior to January 29, 2024, employees were exposed to caught in and pinch point hazards. Multiple belts with both runs 42 inches or less from the floor were not fully guarded. a) The belt located by the front of the truck scale near the office. b) The far side from the office of the smallest bins, located between two 50,000 bushel bins. c) The distributor head of the active leg by the two 100,000 bushel bins. d) The horizontal screw auger located near the office, with a guard only partly attached and an exposed belt.