Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1562706.015
Citation: 01007B
Citation Type: Other
Abatement Status: Not Completed - AD Discretion
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/06/2022
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/02/2022
Gravity: 10
Report ID: 0213900
Contest Date: 05/31/2022
Final Order: 11/30/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 11/30/2022 | $0.00 | 06/02/2022 | Other | |
Penalty | C: Contested | 06/22/2022 | $0.00 | 06/02/2022 | Serious | |
Penalty | Z: Issued | 05/06/2022 | $0.00 | 06/02/2022 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: a) JOHNS MANVILLE, INC., Facility located at 437 North Grove Street, Berlin NJ 08009 - Band Saw/Slitter Machine: The Machine had two unguarded belts and pullies near and around ground level where employees could accidentally have contact, observed on 11/16/2021.