Violation Detail
Standard Cited: 19100147 D05 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1419366.015
Citation: 01007B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/13/2019
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/12/2019
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 09/13/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/13/2019 | $0.00 | 12/12/2019 | Serious | |
Penalty | Z: Issued | 08/13/2019 | $0.00 | 09/30/2019 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.147(d)(5)(i): Following the application of lockout or tagout devices to energy isolating devices, all potentially hazardous stored or residual energy was not relieved, disconnected, restrained, and otherwise rendered safe: At 8502 Mid County Industrial Drive, St. Louis, Missouri, specifically inside of the Liquid Line Department, authorized employee(s) failed to relieve the residual pneumatic energy for the Liquid Line #2 Machine. This violation was noted on 08/02/19.