Standard Cited: 19100219 E01 Mechanical power-transmission apparatus.
Inspection Nr: 1374883.015
Citation: 01007B
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/31/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 07/02/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/02/2019 | $0.00 | Serious | ||
Penalty | Z: Issued | 05/31/2019 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.219(e)(1): The horizontal belt seven (7) feet or less from the floor level was not guarded: Garick, LLC, Cumming, GA - In the bulk mill, employees were exposed to an ingoing nip points from the horizontal belt located less four feet from the ground, under the mill and near a large access opening, on or about 2/1/19.