Violation Detail
Standard Cited: 19101025 I02 I Lead.
Inspection Nr: 1273830.015
Citation: 01007B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/10/2018
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/02/2018
Gravity:
Report ID: 0729300
Contest Date:
Final Order: 05/04/2018
Related Event Code (REC): C
Emphasis:
Substance: 1591
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2018 | $0.00 | 08/02/2018 | Other | |
Penalty | Z: Issued | 04/10/2018 | $0.00 | 05/25/2018 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.1025(i)(2)(i): Clean change rooms were not provided for employees exposed to lead in excess of the permissible exposure limit (PEL), without regard to the use of respirators: 900 Jeffco Executive Drive, Imperial: Employer is exposing employees to hazardous airborne lead levels where employees who are exposed to lead above the permissible exposure level of 50 micrograms per cubic meter of air are not provided clean change rooms. On or about 11/07/2017 an employee who was the "trainer" was exposed to airborne lead at twice the permissible exposure limit (PEL) of 50 micrograms of lead per cubic meter of air as determined by personal air sampling conducted on 11/07/2017 by OSHA. The exposure level obtained was 110 micrograms of air borne lead per cubic meter of air calculated on 8-hour time weighted average basis. Sampling was conducted for 306 minutes. The overexposed employee was not provided a clean change room.