Violation Detail
Standard Cited: 19100219 F01 Mechanical power-transmission apparatus.
Inspection Nr: 1247171.015
Citation: 01007B
Citation Type: Serious
Abatement Date: 09/21/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/04/2017
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): R
Gravity: 5
Report ID: 0729300
Contest Date:
Final Order: 08/22/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/22/2017 | $0.00 | 09/21/2017 | Serious | |
Penalty | Z: Issued | 08/04/2017 | $0.00 | 09/21/2017 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.219(f)(1): Gears were not guarded in accordance with one of the following methods: At 9832 Evergreen Industrial Drive, St. Louis, MO 63123, specifically inside of the Print & Roll Stock Department, the latch lock securing a guard over a series of gears at the PVA Station could be opened by hand instead of a required hand tool or the equivalent. The PVA Station was part of the Retroflex Single-Color Flexo Printer, m/n 20114613, a.k.a. Press #17. One employee opened up the guard to determine the source of a leak and became exposed to unguarded gears. A multiple amputation occurred on or about 07/14/17.