Violation Detail
Standard Cited: 19100213 C03 Woodworking machinery requirements.
Inspection Nr: 1173119.015
Citation: 01007B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/07/2016
Nr Instances: 1
Nr Exposed: 5
Abatement Date: 12/02/2016
Gravity: 5
Report ID: 0524200
Contest Date:
Final Order: 10/27/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/27/2016 | $0.00 | 12/02/2016 | Serious | |
| Penalty | Z: Issued | 10/07/2016 | $0.00 | 10/20/2016 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: (a) Cutting Department - On or about August 26, 2016, the employer did not ensure that the Rockwell 10" Unisaw was furnished with a kickback device to prevent material form squeezing the saw or being thrown back on to the operator. In accordance with the requirements of 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete and must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase, or repair of the equipment, photographic or video evidence of abatement, or other written records.
Translate