Violation Detail
Standard Cited: 19100184 I09 Slings.
Inspection Nr: 1077467.015
Citation: 01007B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/24/2015
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 02/12/2016
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 01/21/2016
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/21/2016 | $0.00 | 02/12/2016 | Serious | |
| Penalty | Z: Issued | 12/24/2015 | $0.00 | 02/12/2016 | Serious |
Text For Citation: 01 Item/Group: 007B Hazard:
29 CFR 1910.184(i)(9): Synthetic web sling(s) were not immediately removed from service for having snags, cuts and tears: a/ At the Danieli Line, specifically at the Pay-Off Area, a synthetic web sling used to move spools of rough raw steel product via an unmarked, overhead crane possessed a hole clear through the material. b/ Inside of Building #2, the synthetic web sling used to move finished steel product via a Demag 7T Underhung Crane, s/n 79192, was badly ripped in multiple places.