Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 999111.015
Citation: 01007A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,900.00
Current Penalty: $4,900.00
Issuance Date: 04/06/2015
Nr Instances: 9
Nr Exposed: 7
Abatement Date: 04/23/2015
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 05/19/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/19/2015 | $4,900.00 | 04/23/2015 | Serious | |
Penalty | Z: Issued | 04/06/2015 | $4,900.00 | 04/23/2015 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. On or about October 8, 2014, employees were exposed to the hazards associated with unexpected start-up of machines in that specific, written Lockout/Tagout procedures were not developed and utilized for equipment/machines such as but not limited to the following: a. In the CNC Department, the #1 Seiki CNC Lathe, Type 4NE, Serial # NE-41538. b. In the CNC Department, the #2 Cadet CNC Lathe, Model L1420, Serial # 09040462 c. In the CNC Department, the #3 Mori Seiki CNC Lathe, Model SL-7. d. In the CNC Department, the #4 Mori Seiki CNC Lathe, Model LL-7. e. In the CNC Department, the #6 Hwacheon CNC Lathe, Model HI-ECO-45, Serial #M073347D1IA. f. In the Saw Department, Saw #1. g. In the Saw Department, Saw #2. h. In the Saw Department, Saw #3. I. In the AmStock Department, the AmStock Saw.