Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1577410.015
Citation: 01007A
Citation Type: Serious
Abatement Status:
Initial Penalty: $5,801.00
Current Penalty: $0.00
Issuance Date: 07/13/2022
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 08/08/2022
Gravity: 5
Report ID: 0316700
Contest Date: 08/05/2022
Final Order: 02/21/2023
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 02/21/2023 | $0.00 | 08/08/2022 | Serious | |
| Penalty | C: Contested | 08/09/2022 | $5,801.00 | 08/08/2022 | Serious | |
| Penalty | Z: Issued | 07/13/2022 | $5,801.00 | 08/08/2022 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.219(d)(1): Pulleys with parts seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): (a) Wardwell 16-Carrier Braiding Machines 1 through 34 - The motor pulleys, with bottom height ranging from 13.5 inches to 23 inches above the floor, and head pulleys, ranging from 42.5 to 48 inches above the floor, at the right side of each Wardwell 16-carrier braider, did not have complete guarding in that the existing guards did not cover the pulleys on the inner sides nor on the head pulleys' periphery near the clutch lever on each machine. In addition, on machines 10, 18, 19, 20, 21, and 22, the existing guards did not cover the motor pulleys on the outer sides, and on machines 11, 12, 14, 15, 29, 33, and 34, the existing guards did not cover the periphery of the motor nor head pulleys, exposing employees to caught-in and entanglement hazards, on or about April 14, 2022. (b) Wardwell 16-Carrier Braiding Machines 2, 8, 10, 16, 17, 18, 19, 20, 21, and 25 - The pulleys connected to the take up spool on each machine did not have adequate guarding, in that the top pulley, at waist height on each machine, had guarding that did not cover the inner side and back periphery of the pulley, and the bottom pulley, at knee height on each machine, had no guarding, exposing employees to caught-in and entanglement hazards, on or about April 14, 2022. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.