Violation Detail
Standard Cited: 19101026 L01 III
Inspection Nr: 1464572.015
Citation: 01007A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,374.00
Current Penalty: $7,374.00
Issuance Date: 05/12/2020
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0317900
Contest Date:
Final Order: 06/08/2020
Related Event Code (REC):
Emphasis:
Substance: 0689
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/08/2020 | $7,374.00 | Serious | ||
| Penalty | Z: Issued | 05/12/2020 | $7,374.00 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.1026(l)(1): The employer did not ensure that all employees who were assigned to workplaces where there was exposure to Hexavalent Chromium were provided with information and training as required by the Hazard Communication Standard 29 CFR 1910.1200: a) Welding Room: An employee, Welder, was exposed to hexavalent chromium while welding, plasma cutting, and carbon arc gouging stainless steel and the employer did not include hexavalent chromium in the hazard communication program, on or about February 26, 2020. No abatement certification or documentation required.
Translate