Violation Detail
Standard Cited: 19100253 B04 I Oxygen-fuel gas welding and cutting.
Inspection Nr: 1445845.015
Citation: 01007A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,940.00
Current Penalty: $3,984.20
Issuance Date: 05/15/2020
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0213400
Contest Date: 06/15/2020
Final Order: 11/23/2020
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | R: Review Commission | 11/23/2020 | $3,984.20 | Serious | ||
Penalty | C: Contested | 06/17/2020 | $6,940.00 | Serious | ||
Penalty | Z: Issued | 05/15/2020 | $6,940.00 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire: a. 81 Chimney Rock Rd., Bridgewater, NJ - Maintenance bay Oxygen cylinders were stored in the same location as acetylene fuel cylinders. The employer authorized employees engaged in vehicle maintenance activities and welding activities to store oxygen and acetylene cylinders directly next to one another. Violation observed on or about November 20, 2019