Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1381338.015
Citation: 01007A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,282.00
Current Penalty: $4,641.00
Issuance Date: 04/30/2019
Nr Instances: 1
Nr Exposed: 47
Abatement Date: 06/03/2019
Gravity: 10
Report ID: 0522500
Contest Date:
Final Order: 05/23/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/23/2019 | $4,641.00 | 06/03/2019 | Serious | |
Penalty | Z: Issued | 04/30/2019 | $9,282.00 | 06/03/2019 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a. On or about February 27, 2019 and at times thereto, employees were exposed to a rotating shaft while operating the Pendu 4400 BS Saw System stacker machine, thereby exposing employees to a caught in hazard.