Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1374883.015
Citation: 01007A
Citation Type: Serious
Abatement Status: Quick Fix
Initial Penalty: $6,159.00
Current Penalty: $3,950.00
Issuance Date: 05/31/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 07/02/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/02/2019 | $3,950.00 | Serious | ||
Penalty | Z: Issued | 05/31/2019 | $6,159.00 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Garick, LLC, Cumming, GA - In the bulk mill, employees were exposed to an ingoing nip points from the belt and pulley located less four feet from the ground, under the mill and near a large access opening, on or about 2/1/19.