Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1308940.015
Citation: 01007A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,543.00
Current Penalty: $0.00
Issuance Date: 08/17/2018
Nr Instances: 1
Nr Exposed: 20
Abatement Date:
Gravity: 1
Report ID: 0215800
Contest Date:
Final Order: 09/10/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/10/2018 | $0.00 | Serious | ||
Penalty | Z: Issued | 08/17/2018 | $5,543.00 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven feet or less above floors or platforms were not enclosed: a) On or about 4/18/2018, In the Bar Mill: A chain and sprocket associated with the Billet Mover, located next to an exit door, was not adequately guarded.