Violation Detail
Standard Cited: 19100107 D02 Spray finishing using flammable and combustible materials.
Inspection Nr: 1172828.015
Citation: 01007A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,988.00
Current Penalty: $1,500.00
Issuance Date: 12/20/2016
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 06/30/2017
Gravity: 10
Report ID: 0134000
Contest Date: 01/17/2017
Final Order: 06/19/2017
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | P: Petition to Mod Abatement | $1,500.00 | 06/30/2017 | Serious | ||
| Penalty | F: Formal Settlement | 06/19/2017 | $1,500.00 | 05/31/2017 | Serious | |
| Penalty | C: Contested | 01/31/2017 | $4,988.00 | 01/25/2017 | Serious | |
| Penalty | Z: Issued | 12/20/2016 | $4,988.00 | 01/25/2017 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.107(d)(2): Mechanical ventilation was not kept in operation at all times while spraying operations was being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted: Location: Paint On or about August 26, 2016, mechanical ventilation was not used for a sufficient time after spraying to allow vapors to be exhausted.
Translate