Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1133442.015
Citation: 01007A
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $10,689.00
Current Penalty: $3,000.00
Issuance Date: 09/16/2016
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 09/26/2016
Gravity: 5
Report ID: 0419400
Contest Date: 10/07/2016
Final Order: 04/21/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/21/2017 | $3,000.00 | 09/26/2016 | Other | |
Penalty | C: Contested | 10/25/2016 | $10,689.00 | 09/26/2016 | Serious | |
Penalty | Z: Issued | 09/16/2016 | $10,689.00 | 09/26/2016 | Serious |
Text For Citation: 01 Item/Group: 007A Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) Offall - On or about June 1, 2016, the rotating shalt on the 2nd feather screw conveyor lacked a guard exposing employees assessing the stairway to the hazard of coming in contact with a rotating part.