Violation Detail
Standard Cited: 19100212 A05 General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 713878.015
Citation: 01007
Citation Type: Serious
Abatement Status:
Initial Penalty: $3,400.00
Current Penalty: $0.00
Issuance Date: 11/26/2012
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 12/29/2012
Gravity: 5
Report ID: 0522500
Contest Date: 12/06/2012
Final Order: 06/03/2013
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 06/03/2013 | $0.00 | 12/29/2012 | Serious | |
| Penalty | C: Contested | 12/17/2012 | $3,400.00 | 12/29/2012 | Serious | |
| Penalty | Z: Issued | 11/26/2012 | $3,400.00 | 12/29/2012 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.212(a)(5): Exposure of blades. When the periphery of the blades of a fan is less than seven (7) feet above the floor or working level, the blades shall be guarded. The guard shall have openings no larger than one-half (1/2) inch. a. In the rail load out office, there was a Q Mark heater fan which was not properly guarded over the blades thereby exposing employees to a caught-in hazard.
Translate