Violation Detail
Standard Cited: 19260452 C02 Additional requirements applicable to specific types of scaffolds.
Inspection Nr: 1810303.015
Citation: 01007
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $8,276.00
Current Penalty: $4,965.60
Issuance Date: 05/27/2025
Nr Instances: 1
Nr Exposed: 4
Abatement Date:
Gravity: 5
Report ID: 0729700
Contest Date:
Final Order: 06/23/2025
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 06/23/2025 | $4,965.60 | Serious | ||
| Penalty | Z: Issued | 05/27/2025 | $8,276.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally, and automatically square and align the vertical members so that the erected scaffold is always plumb, level, and square: At the jobsite located at 9701 W. 53rd St. N., Maize, KS 67101, employees engaged in masonry activities were exposed to fall hazards of 13 feet 1 inch in that the tubular welded frame scaffold was not fully braced to keep the scaffold square and plumb, to secure and to prevent the collapse of the scaffold in the following instances: a) On the second column from the right on the third tier, cross bracing was missing on the front side closest to the entrance of the building. b) On the second column from the right on the second tier, cross bracing was missing on the inner side.
Translate