Violation Detail
Standard Cited: 19260451 C01 General requirements.
Inspection Nr: 1769386.015
Citation: 01007
Citation Type: Serious
Abatement Status: Not Completed - Worksite Changed
Initial Penalty: $5,202.00
Current Penalty: $5,202.00
Issuance Date: 02/14/2025
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 03/06/2025
Gravity: 5
Report ID: 0317000
Contest Date:
Final Order: 04/09/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 02/14/2025 | $5,202.00 | 03/06/2025 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph: a) Jobsite: 2250 E Cambria St, Philadelphia, PA 19134 - On or about August 17, 2024, employees were exposed to fall hazards between approximately 26 feet and 33 feet 2 inches in height while conducting brick laying from a scaffold that was not restrained from tipping.