Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1745840.015
Citation: 01007
Citation Type: Serious
Abatement Status:
Initial Penalty: $14,518.00
Current Penalty: $14,518.00
Issuance Date: 10/10/2024
Nr Instances: 3
Nr Exposed: 3
Abatement Date: 11/06/2024
Gravity: 10
Report ID: 0625400
Contest Date: 11/06/2024
Final Order:
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 02/12/2025 | $14,518.00 | 11/06/2024 | Serious | |
Penalty | Z: Issued | 10/10/2024 | $14,518.00 | 11/06/2024 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Router Department: On or about May 1, 2024, and at times prior thereto, point of operation guarding was not provided on the Top Master equipment #288, #289, and #290 while employees were using to cut table tops.