Violation Detail
Standard Cited: 19100217 C02 I A Mechanical power presses.
Inspection Nr: 1737800.015
Citation: 01007
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $6,400.00
Issuance Date: 08/22/2024
Nr Instances: 2
Nr Exposed: 2
Abatement Date: 10/15/2024
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 09/17/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/17/2024 | $6,400.00 | 10/15/2024 | Serious | |
Penalty | Z: Issued | 08/22/2024 | $11,292.00 | 09/19/2024 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.217(c)(2)(i)(a):Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s) a) On or about March 28, 2024, the employer did not ensure that the Niagra Press#9 have safeguards in place to prevent employees from reaching under to access the point of operation exposing employees to struck by hazards. b) On or about March 28, 2024, the employer did not ensure that the Minster press Type-110 Fixed Base had safeguards in place to prevent employees from reaching under to access the point of operation exposing employees to struck by hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).