Violation Detail
Standard Cited: 19100334 A02 II Use of equipment.
Inspection Nr: 1736697.015
Citation: 01007
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,610.00
Current Penalty: $3,227.00
Issuance Date: 05/21/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 06/18/2024
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/18/2024 | $3,227.00 | Serious | ||
Penalty | Z: Issued | 05/21/2024 | $4,610.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: a) In the shop located at 7211 Anderson Rd, Tampa, FL 33614: On or about 3/20/2024, the employer exposed employees to electrical shock hazards, in that the DeWalt router unit (s/n DMBNXOR) flexible cord was cut and re-taped together exposing employees to energized wires.