Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1654794.015
Citation: 01007
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $15,625.00
Current Penalty: $0.00
Issuance Date: 08/30/2023
Nr Instances: 1
Nr Exposed: 3
Abatement Date:
Gravity: 10
Report ID: 0626700
Contest Date:
Final Order: 09/29/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/29/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 08/30/2023 | $15,625.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the amusement park, where energy controls procedures were not conducted annually for employees inspecting roller coasters such as, but not limited to, the Flare, 22M Giant Loop.