Violation Detail
Standard Cited: 19101053 D01
Inspection Nr: 1529339.015
Citation: 01007
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $6,827.00
Current Penalty: $0.00
Issuance Date: 08/17/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 5
Report ID: 0522000
Contest Date:
Final Order: 09/08/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/08/2021 | $0.00 | Other | ||
Penalty | Z: Issued | 08/17/2021 | $6,827.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
assess the exposure of each employee who is or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2) or the scheduled monitoring option in paragraph (d)(3) of this section. (d)(2) Performance option. The employer shall assess the 8-hour TWA exposure for each employee on the basis of any combination of air monitoring data or objective data sufficient to accurately characterize employee exposures to respirable crystalline silica. (d)(3)(i) Scheduled monitoring option. The employer shall perform initial monitoring to assess the 8-hour TWA exposure for each employee on the basis of one or more personal breathing zone air samples that reflect the exposures of employees on each shift, for each job classification, in each work area. Where several employees perform the same tasks on the same shift and in the same work area, the employer may sample a representative fraction of these employees in order to meet this requirement. In representative sampling, the employer shall sample the employee(s) who are expected to have the highest exposure to respirable crystalline silica. a) On or about July 16, 2021, the employer had not performed an exposure assessment for respirable crystalline silica, which is contained in the Mineral Core (contains 36% to 38% crystalline silica) and Tectonite 900 (contains less than 20% crystalline silica) door cores and are cut to size using an electric panel saw and sanded.